The radio frequency admittance switch is composed of a measuring pole, a shielding pole, and a grounding pole (the threaded part of the installation). When the measuring pole is covered by the material, the admittance value becomes larger, and a switching signal or an alarm current signal is output.The shielding pole is located between the measuring pole and the grounding pole. The signal waveform is exactly the same as the measuring pole, and the two are completely isolated. When the material is attached to the terminal electrode itself, the admittance change between the measuring pole and the grounding pole can be suppressed, and the admittance change between the measuring pole and the tank wall can only be sensed, which can eliminate the error signal generated by the material attachment.
Technical parameters
Working voltage: 9~36VDC (output ripple is less than 100mV), 90~260VAC 50/60Hz
Power consumption: <0.8W@24VDC ,<5VA@240VAC
Output: DPDT double pole double throw relay output, 8 mA/16mA two-wire output
Relay contact capacity: 5A/250VAC
Alarm delay: 0-60s adjustable
Test range: 0.2pF~100nF
Resolution: 0.01pF
Electrical accuracy: 0.05pF
Stability: 0.01%/℃
Maximum process pressure: 20kgf/cm2
Process connection: thread, flange
Process temperature: -40℃~400℃
Ambient temperature: -40℃~80℃
Protection level: IP67
Explosion-proof grade: intrinsically safe and explosion-proof ExiaIICT6